CORROSION INHIBITOR INTENSIFIER – CIA-AS-401

CORROSION INHIBITOR INTENSIFIER – CIA-AS-401

This corrosion inhibitor aid is an organic acid. It is very soluble in HCL. This aid is a very heavy material and not too soluble in HCL at temperatures below 200°F. Intensifier by itself, should never be used to inhibit acid. It is not a stand-alone acid corrosion inhibitor. Reductions in corrosion weight loss can be in the range of 40 to 90% depending on the type of metal exposed. A corrosion intensifier may be used with a corrosion inhibitor to limit high-temperature corrosion rates on J-55, 80, 13 Cr, and coiled tubing. Using this aid inhibits corrosion up to 280°F. The recommended concentration is 10-60 gal/Mgal of aid in HCL acid. Intensifier becomes fully soluble in HCL when the temperature reaches 280°F.

Features

Aid lowers corrosion rates dramatically when used with organic acid inhibitors allowing increased contact time between the acid and exposed steel. This aid may be used with HCL HCL-HF, and HCL-Acetic acids.
Improves Corrosion Protection When used with normal HCI or HCI-HF acid inhibitors Provides acid corrosion protection on most oilfield grade steels. Compatible with most acid additives.

CORROSION INHIBITOR INTENSIFIER

This corrosion inhibitor aid is an organic acid. It is very soluble in HCL. This aid is a very heavy material and not too soluble in HCL at temperatures below 200°F. Intensifier by itself, should never be used to inhibit acid. It is not a stand-alone acid corrosion inhibitor. Reductions in corrosion weight loss can be in the range of 40 to 90% depending on the type of metal exposed. A corrosion intensifier may be used with a corrosion inhibitor to limit high-temperature corrosion rates on J-55, 80, 13 Cr, and coiled tubing. Using this aid inhibits corrosion up to 280°F. The recommended concentration is 10-60 gal/Mgal of aid in HCL acid. Intensifier becomes fully soluble in HCL when the temperature reaches 280°F.

Features

Aid lowers corrosion rates dramatically when used with organic acid inhibitors allowing increased contact time between the acid and exposed steel. This aid may be used with HCL, HCL-HF, and HCL-Acetic acids.
Improves Corrosion Protection When used with normal HCI or HCI-HF acid inhibitors Provides acid corrosion protection on most oilfield grade steels. Compatible with most acid additives.

Mixing Flexibility

Liquid blend easily added to acid-treating fluids.

Compatibility

Compatible with most acid additives

Physical Properties

AppearanceClear liquid
Density (25℃) g/cm31-1.2
Boiling Point (℃)>100
>100 Flash Point>60°C

Version No: 1 Page 1 of2
Catalog Code: TDS10002
Print Date: Aug-09-2022

Benefits

Stimulates higher temperature formations with minimal corrosion of steel tubular Permits high-strength acid systems to be used in stimulating high temperature formations Compatibility and mixing flexibility allow usage with all HCI and HCI-HF acid.

Packing

CIA-AS-401 is packed in 220 lit. Standard polyethylene drum.

Storage conditions

CIA-AS-401 should be stored in tightly closed containers indoors and maintained at normal temperature. In these conditions, the product is stable for 2 years from its production date.

The descriptions, designs, data, and information contained herein are presented in good faith and are based on part energy parmin current knowledge and experience. They are provided for guidance only and do not constitute the agreed contractual quality of the product or a part of part energy parmin terms and conditions of sale. Because many factors may affect the processing or application /use of the product, Part Energy Parmin recommends that the reader carry out its own investigations and tests to determine the suitability of a product for its particular purpose prior to use. It is the responsibility of the recipient of the product to ensure that any proprietary rights and existing laws and legislation are observed. No warranties of any kind, either express or implied, including, but not limited to, warranties of merchantability or fitness for a particular purpose, are made regarding products described or designs, data or information set forth herein, or that the products, descriptions, designs, data or information may be used without infringing the intellectual property rights of others. Any descriptions, designs, data, and information given in this publication may change without prior information. The descriptions, designs, data, and information furnished by Part Energy Parmin hereunder are given gratis and Part Energy Parmin assumes no obligation or liability for the descriptions, designs, data, or information given or results obtained, all such being given and accepted at the reader’s risk.

Reviews

There are no reviews yet.

Be the first to review “CORROSION INHIBITOR INTENSIFIER – CIA-AS-401”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “CORROSION INHIBITOR INTENSIFIER – CIA-AS-401”

Your email address will not be published. Required fields are marked *